logo
Home News

company news about Polyurethane Foam Fire Resistance: Ultimate Guide to Flame Retardant PU Foam (2026)

Certification
china Zhengzhou Bilin New Materials Manufacturing Co., Ltd. certification
china Zhengzhou Bilin New Materials Manufacturing Co., Ltd. certification
Customer Reviews
BILIN has been our trusted partner for years. They consistently deliver top-quality products with exceptional professionalism. Their reliable service and fast delivery always exceed our expectations. A truly outstanding collaboration every time!

—— Rajiv Patel

Great service, great execution—simple! They offer reliable support, reasonable pricing, and excellent options. As my business grows, I’ll definitely keep working with them. Highly recommended!

—— Marcus Reynolds

The communication was excellent, and the requested samples were sent very promptly. We were extremely satisfied with the product quality, and the pricing was very fair. We’d be happy to recommend your products to others seeking similar solutions.

—— David Mitchell

Good quality! We have cooperated with BILIN for a long time. Homey always maintains excellent product quality.

—— Luis Mendoza

Good quality! We have cooperated with Homey for a long time, and our customers feedback that the quality is excellent.

—— Dmitry Volkov

This is a highly professional company with top-quality, high-performance products. Their extensive product line meets all our diverse requirements, and their delivery speed is exceptionally fast. We deeply trust their expertise and outstanding service.

—— Khalid

I'm Online Chat Now
Company News
Polyurethane Foam Fire Resistance: Ultimate Guide to Flame Retardant PU Foam (2026)
Latest company news about Polyurethane Foam Fire Resistance: Ultimate Guide to Flame Retardant PU Foam (2026)
Polyurethane foam (PU foam) is a staple in construction and renovation for gap filling, sealing, and insulation. But when it comes to fire safety, there’s widespread confusion: Is polyurethane foam flammable? Do flame retardant options actually work? Many people mix up “flame retardant” with “non-flammable,” leading to risky product choices that fail building fire codes. Worse, regular PU foam is highly flammable, releasing toxic smoke and molten drips when burned. The good news is that flame retardant polyurethane foam—rated B1/B2 (or B-s1,d0/V-0 for international standards)—solves these issues. This guide breaks down polyurethane foam fire resistance, ratings, flame retardant mechanisms, application scenarios, and buying tips to help you choose safely, comply with regulations, and balance functionality with fire safety.

Is Polyurethane Foam Fire Resistant?

Regular vs. Flame Retardant PU Foam: Core Differences

The fire performance of polyurethane foam depends entirely on its formula. Regular PU foam, made from polyether polyol and isocyanate, has a porous structure filled with flammable gases. It ignites easily when exposed to open flames, spreads fire quickly, and emits toxic fumes like carbon monoxide and hydrogen cyanide—along with molten drips that fuel further combustion. It’s only suitable for enclosed, non-fire-rated areas with no safety requirements, such as internal gaps in non-occupied furniture.
Flame retardant polyurethane foam, by contrast, is modified with non-halogen flame retardants (phosphorus-based, nitrogen-based, or composite blends) to suppress combustion. It achieves “self-extinguishing” when away from flames, produces minimal smoke, and avoids toxic drips. Its fire resistance is classified by specific ratings, making it suitable for areas with fire safety requirements. Note that halogenated flame retardants (e.g., bromine-based) are not recommended—they release toxic halogenated hydrogen when burned, causing secondary pollution and failing EU/US environmental standards.

Key Conclusion: Flame Retardant ≠ Non-Flammable

A common misconception is that flame retardant PU foam is “non-flammable.” In reality, even high-grade flame retardant polyurethane foam only reaches B1-class (difficult to ignite) in fire ratings—it cannot achieve Class A (non-combustible), a standard reserved for inorganic materials like rock wool or fireproof cement. For areas requiring Class A fire resistance, polyurethane foam (even flame retardant versions) is strictly prohibited.

Polyurethane Foam Fire Ratings: Standards & Levels

Chinese National Standard (GB 8624-2012)

Most domestic construction projects follow GB 8624-2012, which classifies flame retardant PU foam into B1 and B2 grades based on combustion heat, flame spread speed, self-extinguishing time, and smoke toxicity:
  • B1 Grade (Class C): Difficult-to-ignite material. It self-extinguishes within 30 seconds after removing the flame, with a flame spread length ≤150mm, no molten drips, and smoke toxicity at Level T1 (low toxicity). It’s designed for critical fire safety areas.
  • B2 Grade (Class D): Combustible material. It self-extinguishes within 60 seconds, controls flame spread, and may have minor non-sustained drips. It’s suitable for general fire safety areas where flame spread needs to be contained.

International Standards (For Overseas Projects)

For global projects, match polyurethane foam fire ratings to regional standards:
  • European Standard (EN 13501-1): The mainstream grade is B-s1,d0, equivalent to Chinese B1 grade. It requires low smoke emission and no drips, making it ideal for commercial buildings in the EU.
  • North American Standard (UL 94): Grades V-0 and V-1 are common. V-0 (the highest) self-extinguishes within 10 seconds, with no drips. It’s mandatory for construction materials in the US and Canada.
  • Australian Standard (AS 1530.3): Group 1 (difficult to ignite) is the core grade for polyurethane foam, aligning with B1-class performance.
Genuine flame retardant PU foam clearly marks its fire rating and standard (e.g., “GB 8624-2012 B1” or “EN 13501-1 B-s1,d0”) on packaging. Products with vague or missing labels are likely non-flame retardant.

How Does Flame Retardant PU Foam Work?

Three Core Flame Retardant Mechanisms

Flame retardant polyurethane foam relies on a synergy of three mechanisms to suppress fire, targeting different stages of combustion:
  1. Vapor-Phase Retardation: When heated, flame retardants decompose to release inert gases (nitrogen, carbon dioxide). These gases dilute flammable vapors in the foam’s pores and block oxygen, starving the flame of fuel.
  2. Condensed-Phase Retardation: Decomposed flame retardants (e.g., phosphoric acid, boric acid) form a dense carbonized layer on the foam’s surface. This layer wraps the flammable base material, preventing flames from spreading inward and reducing drips.
  3. Combustion Chain Interruption: Radical scavengers in the flame retardant capture active free radicals (hydroxyl, hydrogen) produced during combustion. This breaks the combustion chain reaction, stopping the flame from propagating and enabling self-extinguishing.

Flame Retardant Selection: Non-Halogen Is the Trend

Prioritize non-halogen flame retardants (phosphorus-based, nitrogen-based, or composite blends) for environmental and safety reasons. Halogenated flame retardants (e.g., bromine-based) are being phased out globally—they release toxic halogenated hydrogen when burned, posing health risks and failing green building standards. Non-halogen options meet EU REACH and US EPA regulations, making them suitable for high-end and overseas projects.

Where to Use Fire Rated Polyurethane Foam?

Strictly Prohibited Scenarios

Since polyurethane foam (even flame retardant) cannot reach Class A non-combustible status, it’s forbidden in areas requiring Class A fire resistance. Use inorganic alternatives like fireproof rock wool, expanding fire sealant, or fire cement instead:
  • Firewalls, fire partitions, and gaps in fire escape routes/safety exits
  • Electrical switch rooms, generator rooms, boiler rooms, and other high-temperature/flammable areas
  • Curtain wall gaps in high-rise buildings
  • Sealing for fire exhaust ducts

Grade-Specific Application Guide

Match foam grade to the area’s fire safety requirements to ensure compliance:
  • B1 Grade Flame Retardant Foam: For critical fire safety areas, including window/door frame gaps in high-rise buildings, interior renovation in malls/offices (non-firewall areas), ceiling/partition gaps in multi-story buildings, kitchen/gas pipe surroundings (high-temperature/near-open-flame zones), and equipment installation gaps in industrial workshops (non-flammable areas).
  • B2 Grade Flame Retardant Foam: For general fire safety areas, such as interior window/furniture installation gaps in multi-story residences, gap sealing for air conditioning/water supply pipes in offices/residences, and outdoor non-structural gaps (fences, outdoor cabinets).
  • Regular PU Foam: Only for enclosed, non-occupied areas with no fire requirements, such as internal gaps in wardrobes/cabinets, temporary warehouse sealing, and garden facilities (no open flames, no long-term occupancy).

How to Choose the Best Flame Retardant PU Foam?

3 Core Verification Tips

  1. Check Packaging Labels: Ensure clear marking of fire rating, standard, production date, and manufacturer. Avoid products with ambiguous labels like “flame-resistant” without specific grades.
  2. Request Test Reports: Ask suppliers for third-party test certificates (e.g., from China National Building Materials Testing Center, EU CE certification) with valid expiration dates. Reports must specify product model, fire rating, and key indicators (self-extinguishing time, smoke toxicity).
  3. Match to Scenarios: Don’t overpay for B1 grade in areas where B2 suffices, and never use B2 grade in critical fire safety zones. Choose high-temperature resistant flame retardant foam (≥100℃) for kitchens/gas areas.

Avoid Pitfalls: Steer Clear of Fake Flame Retardant Products

Stay vigilant against counterfeit products to ensure fire safety:
  • Reject products with no labels, blurred markings, or fake certification logos.
  • Avoid halogenated flame retardant foam—verify the flame retardant type with suppliers.
  • Choose reputable brands for stable formulas, reliable fire performance, and after-sales support. Avoid unbranded “three-no” products.

Fire Safety Tips for Polyurethane Foam Installation

Even with flame retardant foam, proper installation is key to preventing fires. Follow these guidelines:
  • Keep Away from Open Flames: Uncured foam and its raw materials are flammable. Ban smoking, welding, and open flame lamps in the construction area. Control temperature between 5-35℃ and stay away from heat sources (radiators, water heaters).
  • Dispose of Waste Properly: Uncured foam residue and leftover material in pipes are flammable—collect in sealed bags and discard immediately. Clear cured foam scraps to avoid accumulation.
  • Allow Full Curing: Flame retardant performance only takes effect after full curing (24-48 hours, adjusted for temperature/humidity). Wait for complete curing before painting or tiling.
  • Avoid Spark-Producing Tools: Use non-sparking tools (plastic scrapers) for cutting/curing foam—metal tools may create sparks that ignite foam.
  • Use Fireproof Accessories: In critical fire areas, apply thin steel structure fireproof paint over cured foam to enhance fire resistance.
  • Do Not Modify Formulas: Never mix regular foam with flame retardants—unprofessional modification invalidates fire performance and may cause adhesion failure or air leakage.

FAQ: Polyurethane Foam Fire Resistance

  1. Can flame retardant polyurethane foam be used in fire-rated walls? No. Fire-rated walls require Class A non-combustible materials. Flame retardant PU foam (B1/B2 grade) is forbidden here—use fireproof rock wool instead.
  2. Does thicker PU foam improve fire resistance? No. Fire performance is unrelated to thickness. Excessive foam causes incomplete expansion and loose structure, reducing flame retardancy. Follow product guidelines for dosage.
  3. Is polyurethane foam toxic when burned? Regular foam releases toxic fumes (carbon monoxide, hydrogen cyanide). Flame retardant foam minimizes smoke toxicity (Level T1) but still emits mild fumes when burned—ensure proper ventilation in fire scenarios.
  4. Can I paint over flame retardant PU foam? Yes, but only after full curing. Use water-based or solvent-based paints compatible with PU foam—test a small area first to avoid peeling.
  5. What’s the difference between B1 and B2 PU foam fire ratings? B1 is difficult to ignite (self-extinguishes in 30s, low toxicity), suitable for critical areas. B2 is combustible (self-extinguishes in 60s, controlled flame), for general areas. B1 offers higher fire safety but costs more.

Final Verdict + Actionable CTA

Polyurethane foam’s fire resistance is not inherent—regular foam is flammable, while flame retardant versions (B1/B2 grade) suppress fire via specialized formulas. To use it safely, follow three rules: choose the right grade for your scenario, verify product authenticity, and install correctly. This balances PU foam’s excellent sealing/insulation benefits with fire safety compliance, making it a reliable choice for construction and renovation.
Pub Time : 2026-01-27 17:39:44 >> News list
Contact Details
Zhengzhou Bilin New Materials Manufacturing Co., Ltd.

Contact Person: Mr. Edgar Wang

Tel: +86 15538000653

Send your inquiry directly to us (0 / 3000)